Regeneration interval = usable capacity ÷ grains used a day. Penn State Extension's example: four people × 75 gallons × 10 gpg = 3,000 grains a day; a 20,000-grain unit regenerates about every six to seven days. About weekly is the usual target. A metered valve counts gallons and regenerates when the capacity is used; a timer regenerates on a schedule whether it's needed or not.
Timer vs metered
| Timer | Metered (demand) | |
|---|---|---|
| Triggers on | Days | Gallons used |
| Salt use when water use varies | Higher | Lower |
| Setup | Days between regenerations | Hardness and capacity |
Signs it's not regenerating right
- Hard water returns before the next regeneration: capacity too small, wrong hardness setting, or worn resin.
- Salt level never drops: a bridge in the brine tank or a brine-draw problem.
- Water stays high in the brine tank: see why a brine tank fills with water.
Setting it
Enter your hardness (plus about 4 gpg per ppm of iron) on a metered valve. On a timer, set days from your usable capacity and load; the sizing calculator shows both.
Products mentioned

AFWFilters Fleck 5600SXT 48,000-Grain Water Softener
48,000 grains · Fleck 5600sxt

Fleck 5600SXT 48,000-Grain Water Softener
48,000 grains · Fleck 5600 SXT

Aquasure Harmony Series AS-HS48D 48,000-Grain Water Softener
48,000 grains · 12 GPM